Continuous Ground Gas Monitoring

It is almost inevitable in the initial phases of a construction sites development, that a Ground Gas risk assessment process is required by the local planning authority, and subsequently undertaken by a developer or their contractor. This normally encompasses spot monitoring visits that can last up to 12 months or more, if methane is found at over 5% by volume.

However, it is important to realise that the true objectives of a ground gas monitoring survey period is to determine the true ground gas regime and how that will likely change in the future, it is not just a screening exercise. Currently, this is most commonly achieved by discrete periodic static measurements of ground gas concentrations, from which a ground gas regime is inferred. Nevertheless, this approach is inherently flawed, with the inability to accurately  measure   ground-gas  concentration  and  ground-gas  fluxes. Neither  are  measured  directly  and  both  are  likely  to  be  temporally variable.

Measurement  is  indirect  because  ground-gas  concentration  is  inferred  from  periodic sampling  of  gas  accumulated  within  a  borehole  and  flux  is  then  inferred  from  these borehole  gas  concentrations. The  unit  of  flux  is  volume/time,  therefore  it  cannot  be measured directly without time series data.   With  the  ability  to  collect  time  series  data,  an  improved  measurement  of  flux  can  be made  and  temporal  variability  can  be  quantified  and  accounted  for. This  will  improve understanding  of  processes,  thereby  reducing  the  uncertainty  which  is  inherent  in  the inferences  required  in  using  measurements  that  are  indirect  and  lacking  in  temporall resolution. Contaminated  land  and  landfill  industry  regulators  recognise  the  need  for  more representative  data  but  cost  has  prevented  the  collection  of  continuous  records  of ground-gas  measurements.    However, technology such as the Gasclam in-borehole continuous ground gas monitor allow for such data to be collected. 

The  current  approach  relies  on  discrete  measurements  of  concentration  from  which representative  ground  gas  concentrations  and  gas  migration  potential  are  inferred. However,  as  system  data  is  poorly  resolved  temporally  uncertainties  in  these inferences  remain  large. For  example,  the  frequency  of  variation  in  gas concentration  may  be  higher  than  the  sampling  frequency,  in  which  case measurement  will  not  be  representative. The  benefit  of  continuous  monitoring  in overcoming  the  mismatch  in  sampling  frequency  and  variability  in  the  gas concentration. Importantly,  time  series  data  also  reveals  that  the  frequency  of  variation  in  gas concentration  is  highly  variable.

Higher temporal resolution of not only gas concentration but also other environmental variables allows their inter-relationships to be more clearly defined. This in turn allows dominant controls on gas concentration to be recognised and for better prediction of gas concentration as other parameters change. Atmospheric pressure is considered to be a strong driving force for gas migration (Wilson et al, 2008).  In general it is assumed that concentrations are higher when pressure is low and vice versa and because of this current guidance (e.g. CIRIA Report 665) recommends collecting at least one spot sample below 1000mbar in falling pressure. However, continuous ground gas measurements show the arbitrary nature of the 1000mbar limit and that concentration changes continuously with variances in atmospheric pressure, rather than displaying a clear dependency on the absolute atmospheric pressure. Furthermore, the widely reported relationship between pressure and concentration does not always exist; with the inverse relationship having been observed.

So, we can see that the  ability  to  monitor  environmental  parameters  and  concentration  simultaneously will  provide  an  understanding  of  the  processes  contributing  to  ground-gas  production and  migration.  Initial  results  suggest  that  the  relationship  between  environmental parameters  and  concentration  are  complex  and  currently  poorly  understood.  The potential  for  further  understanding  of  processes  will  allow  for  a  more  representative conceptual  model.  This  has  a  further  impact  on  risk  assessment,  which  is  currently based  on  inferences  of  worst-case  conditions  determined  by  limited  periodic measurements  of  gas  concentration.

It is also common that we have to consider the risk of organics contamination in ground gas in the form of volatile organic compounds (VOCs). These can easily be ignored or misidentified due to ground gas monitors mistakenly identifying them as methane (CH4). This is as a result of the monitor infrared absorbance over methyl groups on methane (R-CH3) which are almost ubiquitously found on most other organic compounds.

As such, Photo Ionisation Detectors (PIDs) are often used to identify the presence of such compounds by spot sampling the ground gas. These are very useful as an initial screening exercise if methane levels are genuinely not present in volumes beyond approximately 4% by volume. Any concentration close to this renders a PID impotent due to methane absorbing the UV output of the PID lamp. Hence, VOC analysis requires to be undertaken, either through grab sampling and laboratory analysis. However, onsite VOC analysis can now be achieved through the use of Micro GC systems, such as the Frog 4000 from Defiant Technologies. This unit allows for full field VOC analysis equivalent to laboratory standards for both qualification and quantification of organic vapours present with target analysts being able to be separated and detected in less than five minutes.

Continuous  gas-monitoring  data  has  revealed  several  potential  flaws  in  the  existing monitoring  methodologies. The  identification  of  ground-gas  regimes  that  vary  on  a site-specific  basis  indicates  the  potential  for  a  mismatch  between  the  frequency  of sampling  and  the  variability  of  gas  concentration,  demonstrating  the  importance  of selecting  an  appropriate  sampling  frequency  to  avoid  missing  valuable  information. This  can  be  clearly  seen  when  comparing  the  concentration  duration  curves  from  the high frequency data and spot sample measurements.

When combining this tool with onsite field analysis of VOCs in boreholes we have a significantly increased potential to get a fuller understanding of the true nature of ground gas regimes and the potential contamination of soils and ground waters with organics.

 

By Dr. Steven Goodman, and adapted from GasClam: Continuous Ground-Gas Monitoring Becomes a Reality, from Dr. Peter Morris